4Sight ophthalmic ultrasound (A-scan, B-scan, UBM, pachymeter)
Keeler Accutome four-in-one ophthalmic ultrasound diagnostics platform: A-scan, B-scan, UBM (ultrasound biomicroscopy of the anterior segment) and pachymeter combined in one portable touchscreen unit, made in the USA. Patient data is passed between modalities, integrated DICOM Worklist, reports shared via EMR, email or printer; the B-scan and UBM probes also work with a Windows PC. A-scan: immersion or contact modes, automatic alignment detection and sclera recognition, Hoffer Q, Holladay I, SRK/T, Haigis, SRK II, Binkhorst II formulas and post-refractive methods. B-scan: 0.015 mm resolution, 2x zoom, unlimited film loops, 12 measuring calipers. 48 MHz UBM: cornea, iris, ciliary body, zonules, crystalline lens and IOL, sulcus-to-sulcus, anterior chamber depth and angle measurement. Pachymeter: ±5 µm accuracy, 9 measurement areas per eye, automated IOP adjustment. Part number 24-8000.
Technical sheet
4Sight unit (part 24-8000): 3.18 kg; 381 x 50.8 x 279.4 mm; touchscreen; kickstand
Connections: HDMI and Ethernet; 5 USB ports; integrated DICOM Worklist; A-scan and pachymeter probe connections
A-scan: 10 MHz; probe 2.23 g, 44.45 x 5.08 mm; immersion or contact; automatic or manual capture; electronic resolution 0.016 mm; clinical accuracy 0.01 mm; 4096 data points per waveform
A-scan eye types: phakic, dense cataract, silicone filled, pseudo PMMA / silicone / acrylic, aphakic (custom types possible); measures ACD, lens thickness, VCD, axial length
A-scan formulas: Hoffer Q, Holladay I, SRK/T, Haigis, SRK II, Binkhorst II; post-refractive: clinical history, contact lens, Shammas clinical, entered
B-scan: 12 or 15 MHz; probe 0.17 kg, 177.8 x 31.75 mm; axial resolution 0.015 mm, lateral 0.085 mm; 60° scanning angle; 2048 points per line; time gain control; 2x zoom; up to 256 frames per scan; 12 measuring calipers
UBM: 48 MHz; probe 0.17 kg, 177.8 x 31.75 mm; axial resolution 0.015 mm, lateral 0.05 mm; 30° scanning angle; 2048 points per line; time gain control; 2x zoom; 12 measuring calipers; USB cable with power isolator
Pachymeter: probe 19 g, 44.45 x 5.08 mm (ø2.5 mm); accuracy ±5 µm; 65 MHz sample rate; range 300–999 µm; automated IOP adjustment
Report / image export: PDF, JPEG, PNG, GIF, TIFF, BITMAP; adjustable gamma (linear, S-curve, log, colour)
Supplied accessories: wireless mouse and keyboard, probe holders (back of the unit), power supply, A-scan immersion shell, manual, quick reference guide, A-scan test blocks, foot switch
Options: B-scan and UBM table-top probe holders, Ergotron mounting arm (wall or table)