Artisan Aphakie - Image principale
Available

Artisan Aphakia

Reference: ARTISAN APHAKIA

PMMA iris-fixated IOL designed for the correction of aphakia. Artisan Aphakia is the #1 backup lens in complicated cataract cases. Based on the long term experience of iris fixation, the Artisan Aphakia IOL is a predictable, safe, high-precision implant. Based on the long-term experience with iris fixation, the Artisan Aphakia IOL is a predictable, safe, high-precision implant that corrects aphakia when it is not correctable by other means. Artisan Aphakia IOLs make your surgery simpler. Retropupillary fixation allows for an easy and fast procedure. Artisan Aphakia is the #1 backup lens in complicated cataract cases. Ultrasound:115.0Optical:115.7 (SRK T)115.7 (SRK II)-0.160 (Haigis aO)0.400 (Haigis a1)0.100 (Haigis a2)3.62 (Hoffer-Q pACD)-0.08 (Holladay 1 sf)0.15 (Barrett suite LF)0 (Barrett suite DF) Ultrasound:116.8Optical:116.9 (SRK T)116.8 (SRK II)-0.250 (Haigis aO)0.400 (Haigis a1)0.100 (Haigis a2)4.34 (Hoffer-Q pACD)0.54 (Holladay 1 sf)0.78 (Barrett suite LF)0 (Barrett suite DF) +2.0 D to +30.0 D (1.0 D increments)+14.5 D to +24.5 D (0.5 D increments) Dr. Adrián Hernández Martínez talks about why the Artisan aphakia IOL is his standard solution for cases without capsular support and provides us with some usefull tips. Dr. Adrián Hernández Martínez implants the Artisan Aphakia IOL in a patient with post-surgical aphakia without capsular support. Dr. Ramon C. Ghanem shares challenging cases and explains why he prefers the Artisan Aphakia IOL to solve these cases. Forlini M, Soliman W, Bratu A, Rossini P, Cavallini G, Forlini C. BMC Ophthalmol. 2015 Oct 27;15:143. doi: 10.1186/s12886-015-0146-4. Sezer Helvac?, Selahaddin Demirdüzen, and Hüseyin Öksüz. Indian J Ophthalmol. 2016 Jan; 64(1): 45–49. Güell JL, Verdaguer P, Elies D, Gris O, Manero F, Mateu-Figueras G, Morral M. J Ophthalmol. 2014 May;98(5):658-63. De Silva SR, Arun K, Anandan M, Glover N, Patel CK, Rosen P. J Cataract Refract Surg. 2011 Sep;37(9):1667-72. Hara S, Borkenstein AF, Ehmer A, Auffarth GU. J Refract Surg. 2011 Oct;27(10):729-35. Rüfer F; Saeger M; Nölle B; Roider J Graefe's Arch. Clin. Exp. Ophthalmology.2008 Baykara M, Ozcetin H, Yilmaz S, Timuçin OB American J of Ophthalmology. 2007; 144(4): 586-91 Tahzib NG, Cheng YY, Nuijts RM Ophthalmology. 2006; 113(6): 976-84 Aspiotis M, Asproudis I, Stefaniotou M, Gorezis S, Psilas K. J Refract Surg. 2006 Jan-Feb;22(1):99-101. Güell JL, Velasco F, Malecaze F, Vazquez M, Gris O, Manero F. J Cataract Refract Surg. 2005 Dec;31(12):2266-71. Ivanka J. van der Meulen, Frans P. Gunning, Muriel G. Vermeulen, Marc D. de Smet. J Cataract Refract Surg. 2004 Dec;30(12):2585-9.

Technical sheet

Reference: Artisan Aphakia, model 205

Manufacturer: Ophtec (Netherlands)

Type: iris-fixated intraocular lens for aphakia (one size fits all), also suitable for retropupillary fixation

Material: PMMA

Abbe number: 47

Powers: +2.0 D to +14.0 D (1.0 D increments); +14.0 D to +25.0 D (0.5 D increments); +25.0 D to +30.0 D (1.0 D increments)

Optic diameter: 5.0 mm, biconvex (convex-plano from +2.0 D to +9.0 D)

Body diameter: 5.4 mm

Overall diameter: 8.5 mm

A-constant ultrasound: 115.0; retropupillary 116.8

Optical constants: SRK/T 115.7; SRK II 115.7; Haigis a0 -0.160, a1 0.400, a2 0.100; Hoffer Q pACD 3.62; Holladay 1 sf -0.08; Barrett LF 0.15, DF 0.0

Retropupillary optical constants: SRK/T 116.9; SRK II 116.8; Haigis a0 -0.250, a1 0.400, a2 0.100; Hoffer Q pACD 4.34; Holladay 1 sf 0.54; Barrett LF 0.78, DF 0.0